. 5800 Refrigerated Sampler Installation and Operation Guide Part #69-5803-086 of Assembly #60-5804-051 Copyright © 2012. All rights reserved, Teledyne Isco Revision H, August 2016. Teledyne Isco recommends that you read this manual completely before placing the equipment in service.
Operation of the equipment. Teledyne Isco recommends that you read this manual completely before placing the equipment in service. Although Teledyne Isco designs reliability into all equipment, there is always the possi-bility of a malfunction. This manual may.
Although Teledyne Isco designs reliability into all equipment, there is always the possibility of a malfunction. This manual may help in diagnosing and repairing the malfunction.
Isco 5800 Refrigerated Sampler Isco 5800 Refrigerated Sampler Safety Information The Isco 5800 Refrigerated Sampler is a “definite purpose” device, intended for use only with compatible Isco equipment. Except as described in this manual, do not use this product with any other manufacturers’. Isco 5800 Refrigerated Sampler General Warnings Before installing, operating, or maintaining this equipment, it is imperative that all hazards and preventive measures are fully understood. While specific hazards may vary according to location and application, take heed in the following general. Isco 5800 Refrigerated Sampler This manual applies Hazard Severity Levels to the safety alerts, Hazard Severity Levels These three levels are described in the sample alerts below. CAUTION Cautions identify a potential hazard, which if not avoided, may result in minor or moderate injury. This category can also warn you of unsafe practices, or conditions that may cause property damage.
Isco 5800 Refrigerated Sampler The equipment and this manual use symbols used to warn of Hazard Symbols hazards. The symbols are explained below. Hazard Symbols Warnings and Cautions The exclamation point within the triangle is a warning sign alerting you of important instructions in the instrument’s technical reference manual. 2.2 5800 Sampler Installation Overview.
Isco 5800 Refrigerated Sampler Table of Contents 3.3.10 Program Options.3-10 3.3.11 Language. A.1 5800 Refrigerated Sampler. 2-12 5800 Sampler to Isco flow meter cable. Features, page 1-2.
Specifications, page 1-4 1.1 Sampler Overview The 5800 Refrigerated Sampler is an automated wastewater sampler that can collect liquid samples from a variety of sources including open channels, sewers, and storm pipe conduits. This indoor/outdoor use sampler is made of durable UV-resistant plastic that provides exceptional resistance to corrosion and weathering. Isco 5800 Refrigerated Sampler Section 1 Introduction 1.2 Features The 5800 Series sampler features are identified in Figure 1-1 and described in Table 1-1. Front View Left View Back View Figure 1-1 5800 Sampler features.
Isco 5800 Refrigerated Sampler Section 1 Introduction Table 1-1 5800 Sampler Features Item Name Description (Fig. 1-1) Control Panel Cover Protects the control panel display and keypad.
Can be locked with user supplied padlock. Control Panel Supports user control and programming of sampler operation. Isco 5800 Refrigerated Sampler Section 1 Introduction 1.3 Specifications Table 1-2 Specifications 132 73 84 cm 52.0 28.8 33.2 in Size (HWD): Weight (empty): 88.5 kg 195 lb Bottle Configurations: 13 configurations available: 24, 1-liter PP. Isco 5800 Refrigerated Sampler Section 1 Introduction Table 1-2 Specifications (Continued) Flow Meter Signal Inputs: 5 to 15 volt DC pulse or 25 millisecond isolated contact closure for Isco flow meters. 4-20 mA input for non-Isco flow meters. Digital Alarms: 4 programmable outputs. Isco 5800 Refrigerated Sampler Section 1 Introduction.
AC power source. Contact Teledyne Isco or its authorized representative for advice. Compare the contents of the boxes with the enclosed packing slip.
If there are any shortages, contact Teledyne Isco immediately. 2.2 5800 Sampler The following sections provide general instructions for placing the sampler into operation. Isco 5800 Refrigerated Sampler Section 2 Installation WARNING If this product is used in a manner not specified in this manual, the protection provided by the equipment may be impaired. WARNING This product has not been approved for use in hazardous locations as defined by the National Electrical Code. Isco 5800 Refrigerated Sampler Section 2 Installation thereby reducing the possibility of sample cross-contamination.
Refer to Table 1-2 for maximum suction line lengths and suction head heights. Security – The sample compartment and pump and control panel have a padlock feature, but the location may need additional security to prevent tampering or vandalism.
Isco 5800 Refrigerated Sampler Section 2 Installation Note To level the sampler, place a bubble level on the installed bottle rack or locating base, then adjust the feet. For one-bottle configurations, place the bubble level on the side rails. CAUTION Do not tip the sampler on its side or back. This delay allows time for the compressor heater to drive off any refrigerant dissolved in the compressor oil. 2.4.1 Backup Power The 5800 is capable of switching the sampler controller to backup power from an Isco lead-acid battery in the event of AC power loss. Note This provides backup power to the sampler controller only. 5800 battery backup module 2.5 Installing a Bottle Kit The 5800 sampler can hold 1, 2, 4, and 24 bottles.
Each of these bottle configurations are supplied as a kit (see Table 2-1), which is normally ordered with the sampler or when you desire to change the bottle configuration. 1-bottle Configuration. Includes one glass 2.5-gallon (10-liter) round bottle, two PTFE lined caps, locating base, and two discharge tubes.
![Teledyne Teledyne](/uploads/1/2/5/4/125492925/299206153.png)
68-5800-018 Single ProPak Configuration for 5800 and 6700 Series FR Refrigerated Sampler. Includes one composite ProPak holder with cap, 100 ProPak bags, two discharge tubes and an instruction sheet. 68-5800-011 1-bottle Configuration.
Then, retest the tube at other arm positions. Note You can order replacement discharge tubes from Teledyne Isco. Order part number 60-9003-279 for a single tube. You can also order bulk tubing rolls from which you can cut to 20 inches (51 cm). Isco 5800 Refrigerated Sampler Section 2 Installation 1. Place the uncapped bottles in the rack (Figure 2-3).
If you are using 350 ml glass bottles, compress the retaining ring and place it in the center of the rack. Release the ring and the outward force of the ring will ®. Isco 5800 Refrigerated Sampler Section 2 Installation Figure 2-4 The 24-bottle rack is held in place by a latch on the left side 2-10. Isco 5800 Refrigerated Sampler Section 2 Installation 2.5.3 4 10L (2.5 Gal) Bottles The four bottle configuration uses a locating base to hold and align the bottles.
To install the base and bottles: 1. Insert the four uncapped bottles into the numbered holes in the locating base 2. Isco 5800 Refrigerated Sampler Section 2 Installation 2.5.5 4, 20L (5 Gal) Bottles 1.
Place the four bottles in the locating base with the bottle mouths positioned above the holes in the base. Slide the locating base into the bottom of the refrigerated compartment. Isco 5800 Refrigerated Sampler Section 2 Installation you place the bottle in any other position liquid will miss the bottle. 20 liter bottle To install the 20 liter bottle: The distributor arm should be removed to prevent it from being an obstruction while you replace the bottle.
The sampler uses a -inch ID suction line of Line lengths from 3 to 99 feet. Teledyne Isco offers vinyl or FEP-lined suction lines. The FEP-lined tubing has a polyethylene jacket to protect it from kinks and abrasions. Isco 5800 Refrigerated Sampler Section 2 Installation Figure 2-8 Attaching the suction line to the pump tubing Once the coupler is attached to the pump tube, removal is difficult, and may require cutting the tube. 2.6.2 FEP-lined Suction Line Inserting a tube coupler into FEP-lined suction line will damage the thin lining. Isco 5800 Refrigerated Sampler Section 2 Installation 2.7 Attaching a Strainer To select the right strainer for your application, see Table 2-2 and Figure 2-10. To attach the strainer to the suction line, carefully screw the strainer’s threaded connector into the suction line.
If attaching the strainer to an FEP-lined suction line, heat the end of the suction line before threading the strainer into the line. Isco 5800 Refrigerated Sampler Section 2 Installation 2.7.1 Alternative to Strainers When sampling from high velocity streams with heavy suspended solids, some field investigations suggest that more representative samples are obtained without the strainer. Consider attaching a short piece of thin walled aluminum tubing to the end of the suction line. Isco 5800 Refrigerated Sampler Section 2 Installation 2.9 Connecting the You can connect the sampler to an external instrument (Figure 2-11) for a variety of reasons. Typical reasons include: Sampler to External Devices.
Receiving flow pulses from a flow meter device for variable time or variable volume sample collection. All of these types of connections use the optional unterminated connect cable, P/N 68-5800-020 (Figure 2-13). This 3 m (10 ft) cable is unterminated at the device end to allow wired connections to compatible circuits. Refer to Table 2-3 for wire identification and connection details. Isco 5800 Refrigerated Sampler Section 2 Installation Figure 2-14 Quick disconnect box 60-2004-228 Table 2-3 Unterminated Connect Cable Sampler Pin Wire Color Signal Name Input/Output Parameters/Comments Black 12 VDC Power Output +14.5 to +12.0 VDC, 0 to1 ampere maximum.
Power for external devices. Isco 5800 Refrigerated Sampler Section 2 Installation 2.10 Configuring and To complete the installation, the sampler software should be configured and programmed. Refer to Section 3 for instructions. Programming the Sampler Configure the sampler to make sure that it “knows” what bottle configuration is installed, the length of the suction line, etc. Isco 5800 Refrigerated Sampler Section 2 Installation 2-22. Isco 5800 Refrigerated Sampler Section 3 Programming In this section.
Control Panel Description. Getting Started, page 3-2. Configuring the Sampler, page 3-3.
Sampling Program Overview, page 3-11. Programming Steps, page 3-15. Programming Examples, page 3-24 3.1 Control Panel. Isco 5800 Refrigerated Sampler Section 3 Programming Table 3-1 Control Button Functions Icon Name Description Power Places the sampler in the On or Standby modes. Note: In either modes, mains power is always con- nected to the refrigeration system.
Numbers Types a number. (section 4.3) will not contain meaningful data until you have run a sampling program. 3.3 Configuring the Before operating the 5800 Sampler, configure the sampler software. Doing so will set the time and date, and allow the Sampler sampler controller to correctly use the hardware and external connections.
Isco 5800 Refrigerated Sampler Section 3 Programming About Times and Dates FIRST SAMPLE AT: ENTER TIME AND DATE: 08:00 16-JUN-12 HH:MM DD-MON-YY Times — Dates — When entering times, use the 24-hour format, When entering dates, use a day-month-year format. Isco 5800 Refrigerated Sampler Section 3 Programming 2.
Press the Number buttons to enter the suction line length. SUCTION LINE LENGTH: ft (3-99) 3. The sampler creates pump tables before returning to the PLEASE WAIT!
SELECT OPTION screen. Isco 5800 Refrigerated Sampler Section 3 Programming 3.3.5 Flow Mode Sampling Select this option to indicate whether or not the sampler should take a sample when the Run Program button is pressed. The Sample At Start option is only applicable to Flow Paced programs. Isco 5800 Refrigerated Sampler Section 3 Programming 3.3.7 Refrigeration Select this option to set the targe t temperature of the refrigeration system.
The sampler will operate the cooling or heating systems as needed to maintain this target temperature. Select the REFRIGERATION option and press Enter. Isco 5800 Refrigerated Sampler Section 3 Programming. PUMPING FORWARD – This event occurs for the duration of the forward pumping step of a sampling event (between pre- and post-purge). PUMPING REVERSE - This event occurs for the duration of the reverse pumping steps of a sampling event (pre- and post-purge). Check the condition of the pump tube regularly and if the tube shows signs of fatigue or wear, replace it immediately. A properly maintained sampler will provide years of reliable service that is expected of a Teledyne Isco Sampler.
them again. Should you forget the password, contact Teledyne Isco’s Customer Service department for assistance.
3.3.11 Language Select this option to change the display language and display units for length measurements. Isco 5800 Refrigerated Sampler Section 3 Programming 3.3.13 Run Diagnostics Select this option to enter the sampler diagnostics mode to test the sampler memory, display, keypad, pump, distributor, and various inputs and outputs. For more information about this service-related feature, refer to Section 5.2.
Isco 5800 Refrigerated Sampler Section 3 Programming Single-bottle samplers can only distribute the sample to the composite bottle therefore skip the steps in this category. Volume instructions define how much liquid is collected at each interval, and the total volume to collect. Isco 5800 Refrigerated Sampler Section 3 Programming PROGRAM CONFIGURE VIEW LOG TIME PACED 3.5.2 FLOW PACED SAMPLE EVERY 3.5.3 HOURSMINUTES One Bottle Multiple Bottles BOTTLES PER 3.5.5 SWITCH SETS EVERY SAMPLE EVENT (1-max) 3.5.7 HOURSMINUTES SWITCH ON TIME 3.5.6. Isco 5800 Refrigerated Sampler Section 3 Programming PROGRAM CONFIGURE VIEW LOG TIME PACED 3.5.2 FLOW PACED SAMPLE EVERY 3.5.4 PULSES (1-9999) One Bottle Multiple Bottles BOTTLES PER 3.5.5 SWITCH BOTTLES EVERY SAMPLE EVENT (1-max) 3.5.7 HOURSMINUTES SWITCH ON TIME 3.5.6. Isco 5800 Refrigerated Sampler Section 3 Programming 3.5 Programming Steps To begin programming from the Main Menu screen, use the Next or Previous arrow to select PROGRAM.
Press the Enter button to display the first programming screen. Refer to Figures 3-3 or 3-4 and the following descriptions. Isco 5800 Refrigerated Sampler Section 3 Programming Use the Next or Previous arrows to select the time or flow option, then press the Enter button. 3.5.3 Sample Every Time Paced Only.
Use the Number buttons to enter the time HoursMinutes interval in hours and minutes. Isco 5800 Refrigerated Sampler Section 3 Programming Table 3-2 Flow Pulse Intervals at Various Input Currents Input Seconds Between% of Full Scale Current (mA) Pulses Flow Rate 17.4 68.75 14.8 81.25 13.7 87.5 12.7 93.75 To calculate the number of flow pulses to enter in this sampler programming screen, follow the steps below.
Isco 5800 Refrigerated Sampler Section 3 Programming Example 1. Consider a flow meter programmed to output 20 mA at 1,000 liters per minute, the peak flow rate of the channel. If you are required to collect a sample every 10,000 liters, you would enter 50 flow pulses according the equation.
Isco 5800 Refrigerated Sampler Section 3 Programming 3.5.7 Switch Bottles/Sets Multiple Bottles Only. If you selected Switch on Time (section Every Hours3.5.6), use the Number buttons to enter the desired time interval Minutes for bottle or bottle set switches. Isco 5800 Refrigerated Sampler Section 3 Programming If you select NO, the sampler will run until it completes the distribution sequence, at which time it stops the program and reports PROGRAM DONE. The sampler will wait in this state until the bottles have been emptied and the program is restarted. To measure the suction head height, refer to Figure 3-5. For most applications, Teledyne Isco recommends that you turn on the liquid detector (Section 3.3.4).
The sampler will automatically calculate the suction head height, typically resulting in more accurate and repeatable sample volumes. Isco 5800 Refrigerated Sampler Section 3 Programming Figure 3-5 Suction Head Height 3.5.19 Pause & Resume The Pause & Resume option allows you to pause the operation of the sampler and then resume operation at a later time and/or date. This option has to be enabled before the sampler is programmed. Isco 5800 Refrigerated Sampler Section 3 Programming Screen you will see when no pairs are set up First screen where you enter in the first pair of Pause & Resume times and days of the week Example of a Pause & Resume. Isco 5800 Refrigerated Sampler Section 3 Programming Note If you enter a “First Sample At” or Start Flow Count At” month less than the current month, the sampler interprets the start time as next year’s date.
3.5.21 Auto Re-Run Use this option when you want to sample on specific days of the week, like Monday, Wednesday, Friday. Isco 5800 Refrigerated Sampler Section 3 Programming. Flow-proportional Constant Time Variable Volume Program Example: Defining the Sample Volume If you have programmed the sampler to USE DEFINED deposit it into the bottle. To measure the delivered SAMPLE (section 3.5.11), follow the steps in this volume, you can replace the bottle with a example to define the volume using pump counts. Isco 5800 Refrigerated Sampler Section 3 Programming Example: Time Paced Sampling Program This example shows how to program the sampler to 7. The sampler displays the Run Continuously collect a 500 ml sample every hour for twenty-four screen.
Select NO to stop the sampling program hours. Isco 5800 Refrigerated Sampler Section 3 Programming Time Paced Sampling Program, continued 13. The sampler displays the Select Days screen.
The sampler displays the Auto Re-Run screen. Day or days when the program is set to run will be Select NO and press Enter. Isco 5800 Refrigerated Sampler Section 3 Programming Example: Flow Paced Sampling Program This example shows how to program the sampler to 5. The sampler displays the Bottle Switch screen.
![Teledyne Teledyne](/uploads/1/2/5/4/125492925/650215430.jpg)
Our collect a 100 ml sample every 10,000 gallons of liquid program requires a bottle switch every 24 hours. Isco 5800 Refrigerated Sampler Section 3 Programming Flow Paced Sampling Program, continued 12. The sampler displays the Start Flow Count screen. The sampler displays the First Valid Day screen. Type “00” and press Enter, then type “00” and Enter the calendar day for the program to begin. Isco 5800 Refrigerated Sampler Section 3 Programming Example: Flow-proportional Constant Time Variable Volume Program This example shows how to program the sampler to Flow screen. Select YES and press Enter.
Collect flow-proportional samples volumes at fixed time VOLUMES DEPENDENT intervals. This program will collect a sample every 15 ON FLOW?. Isco 5800 Refrigerated Sampler Section 4 Operation In this section. Start a Sampler Program. Pause or Stop a Running Program, page 4-3. Post Sampling Activities, page 4-3. View the Log, page 4-3.
Retrieve the Temperature Log, page 4-5. Isco 5800 Refrigerated Sampler Section 4 Operation If the program is set to use a start time, the sampler will wait for the specified time and date.
During this delay, the display for time paced programs will show: FIRST SAMPLE. Isco 5800 Refrigerated Sampler Section 4 Operation 4.2 Pause or Stop a Press Stop to pause a running program.
The sampler will display: Running Program RESUME IN MM:SS VIEW LOG HALT The top line of the display shows a five minute count down timer. Isco 5800 Refrigerated Sampler Section 4 Operation. Exit the log by pressing the Stop button. The log generally contains the following information: 1.
The log reports the number of successful samples out of the COLLECTED total number programmed. OF SAMPLES 2. Isco 5800 Refrigerated Sampler Section 4 Operation Table 4-1 5800 Errors Message Description The sampler was unable to detect liquid. NO LIQUID DETECTED After the sampler detected liquid and while the NO MORE LIQUID sample was being taken, the liquid detector stopped detecting liquid. 1 stop bit No flow control Auto Detect or VT100 terminal emulation.
To sampler To computer Figure 4-1 5800 Sampler to RS-232 serial communication cable (DB9-pin version shown) 5800 Sampler,Model,5800,ID, Current Time,0, Run Time,0, First Sample Time,0, 0. Isco 5800 Refrigerated Sampler Section 4 Operation All times are reported as serial values, which are easily converted to dates and times by spreadsheet programs. The numbers to the left the decimal point are the number of days since January 1, 1900. The numbers to the right are fractional days which can be converted to hours, minutes, and seconds. Isco 5800 Refrigerated Sampler Section 4 Operation Guide Pin Figure 4-3 Sliding the 24-bottle rack out 4.4 Grab Samples Grab samples let you take a single sample on demand and collecting it in an external container.
You can collect a grab sample while the sampler is running a program, paused, or at the Main Menu screen. (Section 3.3.4). These steps also require a graduated cylinder to measure the delivered sample volume. Note Teledyne Isco offers a 1000 ml graduated cylinder.
Order part number 299-0020-00. To calibrate the sample volume: 1. At the Main Menu, press the Calibrate button. Isco 5800 Refrigerated Sampler Section 4 Operation For small volumes, repeat the calibration to ensure that the calibration is averaged and not unduly influenced by normal random variations.
An alternative method using manually defined sample volumes may be helpful for difficult applications. See Section 3.5.10.
This section describes how to maintain and troubleshoot your sampler. If you think your sampler requires repair, or if you have questions concerning its operation or maintenance, contact your authorized Isco service facility or Teledyne Isco’s Technical Service Department: Phone: (800) 228-4373 (USA, Canada, Mexico). Isco 5800 Refrigerated Sampler Section 5 Maintenance WARNING The sampler has a safety interlock that prevents the pump from operating when the pump housing band is open.
DO NOT tamper with the pump housing and band. The pump is extremely powerful. The pump can injure you severely if the sampler activates the pump while you are working on it. Isco 5800 Refrigerated Sampler Section 5 Maintenance Old Pump Rotor New Pump Rotor Figure 5-2 Rollers (A) and guides (B) on the pump rotor b. Pump Rotor – Look for debris build-up on the pump roller, guide surfaces, and pump band (not shown) (Figure 5-2). Isco 5800 Refrigerated Sampler Section 5 Maintenance 2. Loosen the Liquid Detector Cover (F) by unscrewing the large black knob (H).
Unlatch the Pump Housing Band (J). Pull the tube (A) away from the bulkhead fitting (B) and disconnect the tubing coupler and suction line. Isco 5800 Refrigerated Sampler Section 5 Maintenance Example: Resetting the Pump Tube Alarm 1. From the Main Menu screen select CONFIGURE.
You can modify the pump tube alarm setting to tailor it to your needs. The factory default setting is. Isco 5800 Refrigerated Sampler Section 5 Maintenance For application-specific requirements, consult with your laboratory to establish cleaning or replacement protocols. Figure 5-3 Wetted Parts Strainer (316 stainless steel, Bulkhead Fitting (316 stain- polypropylene, or CPVC) less steel) Suction Line (vinyl). TEST 'RAM' 2.
Wait for the sampler to complete the test.TESTING 'RAM' 3. When finished, the sampler displays the test results. 'RAM' PASSED If the sampler reports ‘RAM’ FAILED contact your authorized Isco service facility or the Teledyne Isco factory. 'ROM' PASSED If the sampler reports ‘ROM’ FAILED contact your authorized Isco service facility or the Teledyne Isco factory. For these samplers, the test will report NO CHECKSUM.
This result does not indicate a pass or fail state, only that the ROM test is not valid for this particular sampler. TEST PUMP diagnostic again. If you don’t find obstructions to pump rotor movement, contact your authorized Isco service facility or the Teledyne Isco factory. 5.2.6 Test Distributor The TEST DISTRIBUTOR diagnostic tests the sampler’s. Isco service facility or the Teledyne Isco factory.
They will be able to assist you with o b t a i n i n g a t e st p l u g o r m a k i n g t h e n e c e s sa r y j u m p e r connections to run the test. PCB TEMPERATURE:. C If you suspect that the internal heater is not working, contact your authorized Isco service facility or the Teledyne Isco factory. 5.2.10 Input Voltage The INPUT VOLTAGE diagnostic displays the Main CPU board’s DC voltage supplied by the power module. When this test is started, the sampler will briefly display the input power voltage. Isco 5800 Refrigerated Sampler Section 5 Maintenance The BATTERY VOLTAGE diagnostic displays no-load DC voltage supplied by the internal battery.
When this test is started, the sampler will briefly display the battery voltage. To display the no-load battery voltage: 1. Select the BATTERY VOLTAGE option and press Enter. Isco 5800 Refrigerated Sampler Section 5 Maintenance 5.2.13 Analog Input The ANALOG INPUT diagnostic displays the 4-20 mA current loop input to the sampler.
This diagnostic tool is helpful when troubleshooting an analog input from a flow measurement device. When you start this test, the sampler will display the current reading until you press the Stop or Enter button. Isco 5800 Refrigerated Sampler Section 5 Maintenance 5.3 Temperature Should there be a need to verify the temperature readings displayed by the control panel, it is important to read the Verification temperature as close as possible to the sensor inside the refrigerator. Replacement parts are called out in the following pages. Refer to the call-out in the adjacent table to determine the part number for the item. Replacement parts can be purchased by contacting Teledyne Isco’s Customer Service Department. Teledyne Isco Customer Service Department P.O.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A.1 5800 Refrigerated Sampler. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-10. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-11. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-12.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-13. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-14.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-15. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-16.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-17. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-18. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-19.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-20. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-21. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-22. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-23.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-24. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-25. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-26. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-27. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-28.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-29. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-30.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-31. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A.2 Bottle Configurations A-32.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-33. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-34. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-35. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-36. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-37. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-38. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-39.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-40. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-41. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-42. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-43. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-44. Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-45.
Isco 5800 Refrigerated Sampler Appendix A Replacement Parts List A-46. Isco 5800 Refrigerated Sampler Appendix B General Safety Procedures The safety of the personnel who use the sampler is a critical consideration. The following procedures, applicable to working in and around manholes and sewers, are those used by Black &. Isco 5800 Refrigerated Sampler Appendix B General Safety Procedures This applies to hand tools as well as stones, gravel and other objects. Sharp Edges–Sharp edges of items in or near a manhole may cause cuts or bruises.
Lifting Injuries–Unless proper tools are used to remove manhole covers, back injuries or injuries to hands or feet may result. Isco 5800 Refrigerated Sampler Appendix B General Safety Procedures A person should never enter a manhole unless he is wearing personal safety equipment, including a safety harness and a hard hat. Two persons should be stationed at the surface continuously while anyone is working inside a manhole, to lift him out if he is overcome or injured.
Isco 5800 Refrigerated Sampler Appendix B General Safety Procedures B.4.4 Emergencies Every member of the crew should be instructed on procedures to be followed in cases of an emergency. It is the duty of each crew chief to have a list of emergency phone numbers, including the nearest hospital and ambulance service, police precinct, fire station, and rescue or general emergency number. Isco 5800 Refrigerated Sampler Appendix B General Safety Procedures Whitney, oxygen is equal to 12.2%. Many hikers go there, and to higher peaks as well. After adequate acclimation, they may climb to the top of Mt.
Everest, where oxygen is equal to only 6.7%. Isco 5800 Refrigerated Sampler Appendix B General Safety Procedures concentrations. A supposed safety device that is unreliable is worse than none at all. “Remember that the nose fails, too, when it comes to sensing dangerous concentrations of H “Various other toxic gases have been mentioned in some publications. CE Declaration of Conformity. Name and amount of Hazardous Substances or Elements in the product Hazardous Substances or Elements Component Name (Pb) (Hg) (Cd) (Cr(VI)) (PBB) (PBDE) Circuit Boards Display Wiring Internal Cables Compressor Insulation Insulation Foam Line Cord Power Supply DC Motor Keypad Name and amount of Hazardous Substances or Elements in the product O: Represent the concentration of the hazardous substance in this component’s any homogeneous pieces is.
This warranty applies to the USA and countries where Teledyne Isco does not have an authorized dealer. Customers in countries outside the USA, where Teledyne Isco has an authorized dealer, should contact their Teledyne Isco dealer for warranty service.